2024-03-28T09:08:53Zhttp://digital.csic.es/dspace-oai/requestoai:digital.csic.es:10261/768272020-09-23T13:54:12Zcom_10261_66com_10261_3col_10261_319
In vitro corrosion behaviour and osteoblast response of thermally oxidised Ti6Al4V alloy
García-Alonso, M. C.
Saldaña, L.
Vallés, G.
González-Carrasco, José Luis
González-Cabrero, J.
Martínez, M. E.
Gil-Garay, E.
Munuera, L.
In this work, the influence of thermal oxidation treatments of Ti6Al4V at 500°C and 700°C for 1h on the in vitro corrosion behaviour and osteoblast response is studied. The potential of these treatments, aimed to improve the wear surface performance as biomaterial, relies in the formation of an outer >ceramic> layer of rutile. The corrosion behaviour was evaluated in simulated human fluids by electrochemical impedance spectroscopy and anodic polarisation tests. The effect of these thermal oxidation treatments on osteoblastic behaviour was studied in primary cultures of human osteoblastic cells. Results show that thermal oxidation treatments do not decrease the high in vitro corrosion resistance of the Ti6Al4V alloy. Osteoblast adhesion studies indicate that thermal oxidation treatments do not impair the material biocompatibility. Moreover, the thermal oxidation at 700°C enhances the in vitro osteoblastic cell attachment compared to the thermal oxidation at 500°C. © 2002 Published by Elsevier Science Ltd.
2013-05-27T09:54:43Z
2013-05-27T09:54:43Z
2003
2013-05-27T09:54:43Z
artículo
Biomaterials 24: 19-26 (2003)
http://hdl.handle.net/10261/76827
10.1016/S0142-9612(02)00237-5
eng
closedAccess
Elsevier