FDI and FTC of wind turbines using the interval observer approach and virtual actuators/sensors

AutorBlesa, Joaquim CSIC ORCID ; Rotondo, Damiano CSIC ORCID ; Puig, Vicenç CSIC ORCID ; Nejjari, Fatiha
Palabras claveFault diagnosis
Interval observer
Fault tolerant control
Virtual sensors
Virtual actuators
Wind turbine
Fecha de publicación2014
EditorElsevier
CitaciónControl Engineering Practice 24: 138-155 (2014)
ResumenIn this work, the problem of Fault Detection and Isolation (FDI) and Fault Tolerant Control (FTC) of wind turbines is addressed. Fault detection is based on the use of interval observers and unknown but bounded description of the noise and modeling errors. Fault isolation is based on analyzing the observed fault signatures on-line and matching them with the theoretical ones obtained using structural analysis and a row-reasoning scheme. Fault tolerant control is based on the use of virtual sensors/actuators to deal with sensor and actuator faults, respectively. More precisely, these FTC schemes, that have been proposed previously in state space form, are reformulated in input/output form. Since an active FTC strategy is used, the FTC module uses the information from the FDI module to replace the real faulty sensor/actuator by activating the corresponding virtual sensor/actuator. Virtual actuators/sensors require additionally a fault estimation module to compensate the fault. In this work, a fault estimation approach based on batch least squares is used. The performance of the proposed FDI and FTC schemes is assessed using the proposed fault scenarios considered in the wind turbine benchmark introduced in IFAC SAFEPROCESS 2009. Satisfactory results have been obtained in both FDI and FTC. © 2013 Elsevier Ltd.
Versión del editorhttp://dx.doi.org/10.1016/j.conengprac.2013.11.018
URIhttp://hdl.handle.net/10261/96989
DOI10.1016/j.conengprac.2013.11.018
Identificadoresissn: 0967-0661
Aparece en las colecciones: (IRII) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
FDI and FTC of Wind.pdf602,15 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

117
checked on 06-abr-2024

WEB OF SCIENCETM
Citations

95
checked on 20-feb-2024

Page view(s)

342
checked on 18-abr-2024

Download(s)

345
checked on 18-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.