Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/9099
COMPARTIR / EXPORTAR:
SHARE CORE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Pellegrini, Giulio | en_US |
dc.contributor.author | Campabadal, Francesca | en_US |
dc.contributor.author | Lozano Fantoba, Manuel | en_US |
dc.contributor.author | Martí García, Salvador | en_US |
dc.contributor.author | Miñano, Mercedes | en_US |
dc.contributor.author | Rafí, J. M. | en_US |
dc.contributor.author | Ullán Comes, Miguel | en_US |
dc.date.accessioned | 2008-12-10T12:19:10Z | - |
dc.date.available | 2008-12-10T12:19:10Z | - |
dc.date.issued | 2007-02-04 | en_US |
dc.identifier.citation | Nuclear Instruments & Methods in Physics Research Section A - Accelerators, Spectrometers, Detectors and Associated Equipment 576(1): 95-97 (2007) | en_US |
dc.identifier.issn | 0168-9002 | en_US |
dc.identifier.uri | http://hdl.handle.net/10261/9099 | - |
dc.description | 3 pages, 5 figures.-- PACS nrs.: 29.40.Gx; 29.40.-- ISI Article Identifier: 000247330000023.-- Published in: Proceedings of the 8th International Workshop on Radiation Imaging Detectors. | en_US |
dc.description | Printed version published on Jun 11, 2007. | - |
dc.description.abstract | This work presents results from a new type of edgeless detector, fabricated using an innovative approach to reduce the conventional width of the terminating structure of position sensitive detectors to the detector rim, still using standard planar fabrication technology. A current terminating ring is used to decouple the electrical behaviour of the surface from the sensitive volume within a few tens of micrometres. The detectors, fabricated using a dry etching process to cut the detector as closely as possible to the detector rim, have been illuminated using an infrared laser. The detectors have very high efficiency up to the insensitive area which is located about 25 μm from the detector edge. A detector irradiated with neutrons has also shown good charge collection and lower leakage currents in the current terminating rings compared to non-irradiated ones. | en_US |
dc.format.extent | 2373 bytes | - |
dc.format.mimetype | text/plain | - |
dc.language.iso | eng | en_US |
dc.publisher | Elsevier | en_US |
dc.rights | closedAccess | en_US |
dc.subject | Edgeless detectors | - |
dc.subject | Silicon detectors | - |
dc.subject | Radiation hardness | - |
dc.title | Characterization of edgeless detectors fabricated by dry etching process | en_US |
dc.type | artículo | en_US |
dc.identifier.doi | 10.1016/j.nima.2007.01.128 | - |
dc.description.peerreviewed | Peer reviewed | en_US |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.nima.2007.01.128 | - |
dc.type.coar | http://purl.org/coar/resource_type/c_6501 | es_ES |
item.openairetype | artículo | - |
item.grantfulltext | none | - |
item.cerifentitytype | Publications | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.fulltext | No Fulltext | - |
item.languageiso639-1 | en | - |
Aparece en las colecciones: | (IFIC) Artículos (IMB-CNM) Artículos |
CORE Recommender
SCOPUSTM
Citations
2
checked on 16-abr-2024
WEB OF SCIENCETM
Citations
2
checked on 14-feb-2024
Page view(s)
498
checked on 22-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.