Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/9049
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Suitability of Filofocon A and PMMA for experimental models in excimer laser ablation refractive surgery

AutorDorronsoro, Carlos CSIC ORCID; Siegel, Jan CSIC ORCID ; Remón, Laura CSIC ORCID; Marcos, Susana CSIC ORCID
Palabras clave[OCIS] Ablation of tissue
[OCIS] Medical optics instrumentation
[OCIS] Surface measurements, figure
[OCIS] Laser materials processing
[OCIS] Physiological optics
[OCIS] Ophthalmic optics
[OCIS] Visual optics, refractive surgery
[OCIS] Aberration compensation
Fecha de publicación3-dic-2008
EditorOptical Society of America
CitaciónOptics Express 16(25): 20955-20967 (2008)
ResumenExperimental corneal models in plastic (in PMMA, and more recently in Filofocon A, a contact lens material) have been proposed recently to overcome some of the limitations of the theoretical approaches aiming at improving the predictability of corneal reshaping by laser ablation. These models have also been proposed for accurate assessment of corneal laser ablation patterns. In this study Filofocon A and PMMA optical and ablation properties were studied using an experimental excimer laser set-up. The effective absorption coefficient and the ablation thresholds of these materials were obtained as a function of the number of pulses. Both materials follow a Beer-Lambert law in the range of fluences used in refractive surgery, and the number of incubation pulses is less than 4 (PMMA) and 2 (Filofocon A) above 140 mJ/cm2. We found that above 40 pulses for Filofocon A and 70 pulses for PMMA, ablation threshold and effective absorption coefficients can be considered constant (Fth = 90 mJ/cm2 and α(eff) = 36000 cm-1, for Filofocon A, and Fth = 67 mJ/cm2 and α(eff) = 52000 cm-1 for PMMA, respectively). The absence of ablation artifacts (central islands), a lower number of incubation pulses, a lower pulse-number dependence of the ablation threshold, and a good correspondence between α(eff) and the absorption coefficient α estimated from spectroscopic measurements make Filofocon A a more appropriate material than PMMA for experimental models in refractive surgery and for calibration of clinical lasers.
Descripción13 pages, 7 figures.-- OCIS codes: 170.1020, 170.3890, 120.6650, 140.3390, 330.5370, 330.4460, 330.7335, 220.1000.
Versión del editorhttp://dx.doi.org/10.1364/OE.16.020955
URIhttp://hdl.handle.net/10261/9049
DOI10.1364/OE.16.020955
ISSN1094-4087
Aparece en las colecciones: (CFMAC-IO) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
Suitability_of_Filofocon.pdf247,69 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

29
checked on 20-abr-2024

WEB OF SCIENCETM
Citations

23
checked on 26-feb-2024

Page view(s)

377
checked on 22-abr-2024

Download(s)

315
checked on 22-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.