Please use this identifier to cite or link to this item:
http://hdl.handle.net/10261/8816
Share/Export:
![]() ![]() |
|
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Title: | Monochromatic aberrations and point-spread functions of the human eye across the visual field |
Authors: | Navarro, Rafael; Moreno Barriuso, Esther; Dorronsoro, Carlos CSIC ORCID | Keywords: | Human eye Optical quality Monochromatic aberrations Laser ray tracing Root-mean-square (RMS) wavefront error [OCIS] Vision, color, and visual optics: Vision, color, and visual optics [OCIS] Vision, color, and visual optics: Physiological optics |
Issue Date: | 1-Sep-1998 | Publisher: | Optical Society of America | Citation: | Journal of the Optical Society of America A 15(9): 2522-2529 (1998) | Abstract: | The monochromatic aberrations of the human eye along the temporal meridian are studied by a novel laser ray-tracing method. It consists of delivering a narrow laser pencil into the eye through a given point on the pupil and recording the aerial image of the retinal spot with a CCD camera. The relative displacement of this image is proportional to the geometrical aberration of the ray (laser pencil) at the retina. We scanned the pupils of four observers in steps of 1 mm (effective diameter, 6.7 mm) and for five field angles (0°, 5°, 10°, 20°, and 40°). In addition, the aerial image for each chief ray is a low-pass-filtered version of the retinal pointspread function corresponding to a fully dilated pupil. The resulting spot diagrams, displaying the distribution of ray aberrations, are highly correlated with these point-spread functions. We have estimated the wavefront error by fitting Zernike polynomials (up to the fifth order). Despite the large variation found among observers, the overall rms wave-front error is relatively homogeneous. At the fovea, the average rms value was 1.49 mm when the second-order terms (defocus and astigmatism) were considered; this was reduced to 0.45 mm when the second-order terms were ignored. The rms values increase slowly, in a roughly linear fashion with eccentricity, such that at 40° they are approximately double. These results are consistent with previous findings on the off-axis optical quality of the eye. | Description: | 8 pages, 6 figures.-- OCIS codes: 330.5370, 330.0330.-- PMID: 9729864 [PubMed]. | Publisher version (URL): | http://dx.doi.org/10.1364/JOSAA.15.002522 | URI: | http://hdl.handle.net/10261/8816 | DOI: | 10.1364/JOSAA.15.002522 | ISSN: | 1084-7529 |
Appears in Collections: | (CFMAC-IO) Artículos |
Show full item record
Review this work
SCOPUSTM
Citations
116
checked on May 23, 2022
WEB OF SCIENCETM
Citations
108
checked on May 27, 2022
Page view(s)
375
checked on May 28, 2022
Google ScholarTM
Check
Altmetric
Dimensions
WARNING: Items in Digital.CSIC are protected by copyright, with all rights reserved, unless otherwise indicated.