English   español  
Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/81948
Compartir / Impacto:
Título : Comparison of X-ray CT and MRI of watercore disorder of different apple cultivars
Autor : Herremans, Els; Melado-Herreros, Ángela; Defraeye, Thijs; Verlinden, Bert; Hertog, Maarten; Verboven, Pieter; Val Falcón, Jesús ; Fernández-Valle, Encarnación; Bongaers, Evi; Estrade, Pascal; Wevers, Martine; Barreiro Elorza, Pilar; Bart M., Nicolaï
Palabras clave : Automatic segmentation
Histogram analysis
Microstructure
MRI
X-ray CT
Watercore disorder
Fecha de publicación : ene-2014
Editor: Elsevier
Citación : Herremans E, Melado-Herreros A, Defraeye T, Verlinden B, Hertog M, Verboven P, Val J, Fernández-Valle ME, Bongaers E, Estrade P, Wevers M, Barreiro P, Nicolaï BM. Comparison of X-ray CT and MRI of watercore disorder of different apple cultivars. Postharvest Biology and Technology 87: 42-50 (2014)
Resumen: Watercore is an internal disorder that appears as water-soaked, glassy regions near the core in apples. Fast and non-destructive solutions for sensing watercore would be readily accepted in the postharvest industry. X-ray CT and MRI were compared as potential imaging technologies for detecting this particular disorder. After matching the 3D datasets of X-ray CT and MRI, the images that were obtained on identical fruit were compared quantitatively. Both MRI and CT were able to detect watercore, however the contrast in MRI images was superior. High-resolution micro-CT images showed the microstructural changes in watercore fruit: the intercellular spaces of the affected apple tissue are filled with water. This explained the higher density that is detected here by the X-rays and the higher water content in the MRI. Mean and variance of the frequency distribution of MRI and X-ray CT intensity appeared to be a parameter that allows the identification of healthy apples from affected fruit. Automatic image processing based on thresholding the images resulted in comparable watercore classification accuracy of up to 89% for X-ray CT and 79% for MRI data, despite the better contrast in the MRI images.
Descripción : 9 Págs., 7 Figs. The definitive version is available at: http://www.sciencedirect.com/science/journal/09255214
Versión del editor: http://dx.doi.org/10.1016/j.postharvbio.2013.08.008
URI : http://hdl.handle.net/10261/81948
DOI: 10.1016/j.postharvbio.2013.08.008
ISSN: 0925-5214
Aparece en las colecciones: (EEAD) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
mod vers.aut pend.pdf20,83 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo
 



NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.