Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/60483
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Campo DC Valor Lengua/Idioma
dc.contributor.authorCal-González, J.es_ES
dc.contributor.authorHerraiz, Joaquin L.es_ES
dc.contributor.authorEspaña, Samueles_ES
dc.contributor.authorVicente-Alique, Ernestoes_ES
dc.contributor.authorHerranz, E.es_ES
dc.contributor.authorDesco, M.es_ES
dc.contributor.authorVaquero, J.J.es_ES
dc.contributor.authorUdías, J.M.es_ES
dc.date.accessioned2012-11-16T12:32:11Z-
dc.date.available2012-11-16T12:32:11Z-
dc.date.issued2011-
dc.identifierdoi: 10.1016/j.nima.2010.12.041-
dc.identifierissn: 0168-9002-
dc.identifier.citationNuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment 648: S172- S175 (2011)es_ES
dc.identifier.urihttp://hdl.handle.net/10261/60483-
dc.description.abstractPositron range limits the spatial resolution of PET images and has a different effect for different isotopes and positron propagation materials. Therefore it is important to consider it during image reconstruction, in order to obtain optimal image quality. Positron range distributions for most common isotopes used in PET in different materials were computed using the Monte Carlo simulations with PeneloPET. The range profiles were introduced into the 3D OSEM image reconstruction software FIRST and employed to blur the image either in the forward projection or in the forward and backward projection. The blurring introduced takes into account the different materials in which the positron propagates. Information on these materials may be obtained, for instance, from a segmentation of a CT image. The results of introducing positron blurring in both forward and backward projection operations was compared to using it only during forward projection. Further, the effect of different shapes of positron range profile in the quality of the reconstructed images with positron range correction was studied. For high positron energy isotopes, the reconstructed images show significant improvement in spatial resolution when positron range is taken into account during reconstruction, compared to reconstructions without positron range modeling. © 2010 Elsevier B.V. All rights reserved.-
dc.description.sponsorshipThis work has been supported by the MEC (FPA2007-62216), the UCM (Grupos UCM, 910059), the CPAN (Consolider-Ingenio 2010)CSPD-2007-00042, the RECAVA-RETIC network, ARTEMISS2009/DPI-1802, the European Regional Development and ENTEPRASE grant, PSE-300000-2009-5 and the Ministerio de Ciencia e Innovación, Spanish Government.-
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsclosedAccess-
dc.titleStudy of CT-based positron range correction in high resolution 3D PET imaginges_ES
dc.typeartículoes_ES
dc.identifier.doi10.1016/j.nima.2010.12.041-
dc.date.updated2012-11-16T12:32:11Z-
dc.description.versionPeer Reviewed-
dc.relation.csices_ES
dc.type.coarhttp://purl.org/coar/resource_type/c_6501es_ES
item.openairetypeartículo-
item.cerifentitytypePublications-
item.languageiso639-1en-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextNo Fulltext-
Aparece en las colecciones: (CFMAC-IEM) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Show simple item record

CORE Recommender

SCOPUSTM   
Citations

18
checked on 27-mar-2024

WEB OF SCIENCETM
Citations

16
checked on 29-feb-2024

Page view(s)

328
checked on 28-mar-2024

Download(s)

106
checked on 28-mar-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.