Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/58946
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Is independent component analysis appropriate for multivariate resolution in analytical chemistry?

AutorParastar, Hadi; Jalali-Heravi, Mehdi; Tauler, Romà CSIC ORCID
Palabras claveIndependence
Independent component analysis (ICA)
Mean-field independent component analysis (MFICA)
Multivariate calibration
Multivariate classification
Multivariate curve resolution (MCR)
Multivariate curve resolution-alternating least squares (MCR-ALS)
Mutual information (MI)
Rotational ambiguity
Signal processing
Fecha de publicación2011
EditorElsevier
CitaciónTRAC - Trends in Analytical Chemistry 31: 134–143 (2011)
ResumenIn this article, we examine Independent Component Analysis (ICA) and the concept of Mutual information (MI) as a quantitative measure of independence from the point of view of analytical chemistry. We compare results obtained by different ICA methods with results obtained by Multivariate Curve Resolution Alternating Least Squares (MCR-ALS). These results have shown that, when non-negativity constraints are applied, values of MI increase considerably and the resolved components cannot anymore be considered to be independent (i.e. they can only be considered to be the “least dependent” components). MI values of profiles resolved by MCR-ALS and ICA did not differ significantly when non-negativity constraints were applied. In addition, since data-fitting values were also practically the same in both cases, the solutions provided by them should be considered equivalent from a mathematical point of view and within the region of feasible solutions for the particular set of applied constraints. We therefore conclude that the solutions based only on the independence concept are not necessarily better from the point of view of analytical chemistry than those obtained by other proposed MCR methods. Results obtained in this work also show that ICA can be considered an alternative tool for resolving mixed signals only in a limited number of cases.
Versión del editorhttp://dx.doi.org/10.1016/j.trac.2011.07.010
URIhttp://hdl.handle.net/10261/58946
DOI10.1016/j.trac.2011.07.010
ISSN0165-9936
Aparece en las colecciones: (IDAEA) Artículos

Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

70
checked on 09-abr-2024

WEB OF SCIENCETM
Citations

66
checked on 24-feb-2024

Page view(s)

305
checked on 19-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.