Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/54481
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Experimental evaluation of optimized ablation patterns for laser refractive surgery

AutorDorronsoro, Carlos CSIC ORCID; Remón, Laura CSIC ORCID; Merayo-Lloves, Jesús; Marcos, Susana CSIC ORCID
Fecha de publicación2009
EditorOptical Society of America
CitaciónOptics Express 17: 15292- 15307 (2009)
ResumenA new experimental model based on plastic (Filofocon A) artificial eyes was used to study the ablation profiles and the outcomes of three state-of-the-art refractive surgery excimer lasers provided with narrow-beam flying spot and optimized algorithms (Ladarvision 4000, Alcon; Technolas 217 Z100, Bausch&Lomb Allegretto wave Eye-Q, Wavelight). The 3-D ablation patterns produced by myopic laser corrections (-9, -6 and -3 D) on flat and spherical surfaces of Filofocon A were measured using high resolution optical profilometry. We found significant differences across lasers in the shape and depth of the ablation patterns. A comparison of the ablation patterns on flat and on spherical surfaces provided a measurement of the laser efficiency losses from the center to the periphery at each point of the spherical plastic corneas. This effect also varied across lasers, depending on their fluence (120-400 mJ/cm2). Estimates of the post-operative corneal shapes were obtained from the measurement on Filofocon A and plastic-corneal tissue correction factors. The predicted post-operative corneal ablation shape, ablated volume, asphericity and spherical aberration varied across lasers, as well as the relative contribution of ablation pattern designs and efficiency losses to the increased asphericity. Although the results show that the algorithms have been optimized to reduce the induction of spherical aberration, they would still benefit from the application of correction factors for efficiency effects derived from a systematic approach using experimental plastic models. These models have proved useful (1) to assess the outcomes of different lasers or ablation algorithms, (2) for precise calibration and testing of the lasers, and (3) to calculate experimental correction factors for efficiency effects. ©2009 Optical Society of America.
URIhttp://hdl.handle.net/10261/54481
DOI10.1364/OE.17.015292
Identificadoresdoi: 10.1364/OE.17.015292
issn: 1094-4087
Aparece en las colecciones: (CFMAC-IO) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
Dorronsoro.pdf1,03 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

28
checked on 20-abr-2024

WEB OF SCIENCETM
Citations

27
checked on 25-feb-2024

Page view(s)

293
checked on 23-abr-2024

Download(s)

225
checked on 23-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.