Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/50944
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Campo DC Valor Lengua/Idioma
dc.contributor.authorPacios, Merce-
dc.contributor.authorYilmaz, N.-
dc.contributor.authorMartín-Fernández, I.-
dc.contributor.authorVilla, Rosa-
dc.contributor.authorGodignon, Philippe-
dc.contributor.authorValle, Manel del-
dc.contributor.authorBartrolí, J.-
dc.contributor.authorEsplandiú, María J.-
dc.date.accessioned2012-06-06T09:42:58Z-
dc.date.available2012-06-06T09:42:58Z-
dc.date.issued2012-
dc.identifierdoi: 10.1016/j.snb.2011.12.048-
dc.identifierissn: 0925-4005-
dc.identifier.citationSensors and Actuators, B: Chemical 162(1): 120-127 (2012)-
dc.identifier.urihttp://hdl.handle.net/10261/50944-
dc.description.abstractWe present a simple approach for DNA detection which profits from the use of miniaturized carbon nanotube (CNT) electrodes, Ru(NH 3) 6 2+/3+ as redox DNA hybridization reporters and sensitive but simple electrochemical techniques (chronocoulometry and impedance spectroscopy). The manufacturing process employed in this work yielded robust, highly controlled and well-defined microelectrode arrays of vertically aligned multi-walled CNTs which facilitated very reproducible electroanalytical measurements. The hybridization process and its efficiency were monitored and quantified with chronocoulometric measurements by following up the Ru(NH 3) 6 2+/3+ adsorption at the DNA phosphate backbone. Limits of detection of 1 nM and an efficiency of nearly 100% were found with such methodology. One of the advantages of using CNT microelectrodes is that the scaling down of the electrode size allows the impedimetric detection with such highly positively charged redox reporters, using the charge transfer resistance as an indicator of the DNA hybridization. Such detection scheme would not have been possible in macroscopic CNT electrodes due to the dominance of the diffusion controlled processes. Limits of detection of 100 pM were achieved using the impedimetric technique. The combination of the miniaturized and robust CNT-based electrodes, the advantages of the chosen redox reporter and the electrochemical techniques provide a very simple, reproducible and efficient strategy that could facilitate genosensing and diagnosis. © 2011 Elsevier B.V. All rights reserved.-
dc.language.isoeng-
dc.publisherElsevier-
dc.rightsclosedAccess-
dc.titleA simple approach for DNA detection on carbon nanotube microelectrode arrays-
dc.typeartículo-
dc.identifier.doi10.1016/j.snb.2011.12.048-
dc.date.updated2012-06-06T09:42:59Z-
dc.description.versionPeer Reviewed-
dc.type.coarhttp://purl.org/coar/resource_type/c_6501es_ES
item.openairetypeartículo-
item.grantfulltextnone-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextNo Fulltext-
item.languageiso639-1en-
Aparece en las colecciones: (CIN2) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Show simple item record

CORE Recommender

SCOPUSTM   
Citations

11
checked on 16-abr-2024

WEB OF SCIENCETM
Citations

10
checked on 21-feb-2024

Page view(s)

322
checked on 19-abr-2024

Download(s)

107
checked on 19-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.