Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/44956
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Comparative study of fluoride conversion coatings formed on biodegradable powder metallurgy Mg: The effect of chlorides at physiological level

AutorPereda, M. D.; Alonso, C. CSIC ORCID; Gamero, Miriam; Valle, Jorge del CSIC; Fernández Lorenzo de Mele, Mónica
Palabras claveMagnesium
Fluoride conversion coating
Chloride
Biodegradable
Powder metallurgy
Biomaterials
Fecha de publicación2011
EditorElsevier
CitaciónMaterials Science and Engineering C 31 (5) : 858–865 (2011)
ResumenThe development of a biodegradable metallic implant demands a precisely defined degradation profile and adequate mechanical properties. Mg has been proposed for this purpose but it has an excessively high corrosion rate and insufficient yield strength. In the present work pure Mg mechanically reinforced by a powder metallurgy (Mg(PM)) route and treated with KF was used. The effect of chlorides, at the physiological level, on four fluoride conversion coatings (F-CC) formed on Mg(PM) was evaluated comparatively. The behavior of Mg(PM) during fluoride treatments (0.01 M–0.3 Mfluoride-containing solutions) before and after the addition of chlorides (8 g L−1 NaCl) was investigated by conventional corrosion techniques and by scanning electrochemical microscopy (SECM) complemented with SEM observations and EDX analysis. Results showed that the composition and the microstructural characteristics of the F-CCs as well as their corrosion behavior change with KF concentration and immersion time. Treatments in the 0.01 M–0.1 M KF range prove to be effective to protect Mg(PM) against corrosion in the absence of chlorides while higher KF solution concentration (0.3 M) adversely affects the corrosion resistance of this metal. In the presence of chloride ions the F-CCs progressively lose their fluoride content and their corrosion resistance at a rate that depends on the treatment conditions. Such temporary corrosion protection is appropriate for biodegradable implants.
Versión del editorhttp://dx.doi.org/10.1016/j.msec.2011.01.010
URIhttp://hdl.handle.net/10261/44956
DOI10.1016/j.msec.2011.01.010
ISSN0928-4931
Aparece en las colecciones: (CENIM) Artículos




Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

48
checked on 24-abr-2024

WEB OF SCIENCETM
Citations

46
checked on 26-feb-2024

Page view(s)

329
checked on 24-abr-2024

Download(s)

414
checked on 24-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.