Title

Equipo comparativo para la medida de conductividad térmica de materiales cerámicos

Other TitlesComparative equipment for the measurement of the thermal conductivity
AuthorsBarea, Rafael; Marín Marín, Ricardo; Osendi, María Isabel ; Martínez, R.; Miranzo López, Pilar
KeywordsConductividad térmica
Difusividad térmica
Método comparativo
Materiales porosos
Mullita
Thermal conductivity
Thermal diffusivity
Comparative method
Porous materials
Mullite
Issue DateMar-2006
PublisherSociedad Española de Cerámica y Vidrio
CitationBoletín de la Sociedad Española de Cerámica y Vidrio 45(2): 80-86 (2006)
Abstract[ES] Entre las distintas técnicas de medida de la conductividad térmica de materiales, el método comparativo, recogido en la norma ASTM E1225-99, es el más adecuado para muestras porosas o materiales compuestos. Este método permite determinar conductividades térmicas en estado estacionario, en el intervalo de valores de 0,2 a 200 W/mK, y a temperaturas de ensayo en el rango 100-1300 K, dependiendo del diseño del equipo. En este trabajo se expone el diseño, desarrollo y puesta a punto de un equipo de medida de conductividad térmica basado en este método. Paralelamente, se realiza una validación del equipo mediante el estudio comparativo de los resultados obtenidos usando el equipo comparativo y la técnica del pulso láser en materiales porosos de mullita.
[EN] Among the different techniques available for measuring thermal conductivity, the comparative method (ASTM E1225-99) is the most appropriate for porous materials. This method determines the thermal conductivity in steady state conditions in the 100 - 1300 K temperature range and for conductivities between 0.2 and 200 W/mK, respectively, depending on the equipment characteristics. In the present paper, the design and development, as well as the start up process, of an apparatus based on this method is described. Thermal conductivity data on a mullite based refractory, measured by both the laser flash and the comparative methods, are presented and comparatively discussed in order to validate the developed equipment.
Publisher version (URL)http://boletines.secv.es/es/index.php?id=5&vol=45
URIhttp://hdl.handle.net/10261/4134
ISSN0366-3175
Appears in Collections:(ICV) Artículos
Files in This Item:
File Description SizeFormat 
conductividad.pdf341,34 kBAdobe PDFThumbnail
View/Open
Show full item record
Review this work
 


WARNING: Items in Digital.CSIC are protected by copyright, with all rights reserved, unless otherwise indicated.