Open Access item Validation and reconstruction of flow meter data in the Barcelona water distribution network

Authors:Quevedo, J.
Puig, Vicenç
Cembrano, G.
Blanch, J.
Keywords:Water distribution network, Telecontrol system, Flow meter, Fault detection, Sensor failure, Fuzzy logic classifier
Issue Date:Jun-2010
Publisher:Elsevier
Citation:Control Engineering Practice 18(6): 640-651 (2010)
Abstract:This paper presents a signal analysis methodology to validate (detect) and reconstruct the missing and false data of a large set of flow meters in the telecontrol system of a water distribution network. The proposed methodology is based on two time-scale forecasting models: a daily model based on a ARIMA time series, while the 10-min model is based on distributing the daily flow using a 10-min demand pattern. The demand patterns have been determined using two methods: correlation analysis and an unsupervised fuzzy logic classification, named LAMDA algorithm. Finally, the proposed methodology has been applied to the Barcelona water distribution network, providing very good results.
Description:12 páginas, 16 figuras, 1 tabla.-- El PDF es la versión pre-print.-- et al.