Please use this identifier to cite or link to this item: http://hdl.handle.net/10261/39348
Share/Impact:
Título : Validation and reconstruction of flow meter data in the Barcelona water distribution network
Autor : Quevedo, J., Puig, Vicenç, Cembrano, G., Blanch, J.
Palabras clave : Water distribution network
Telecontrol system
Flow meter
Fault detection
Sensor failure
Fuzzy logic classifier
Fecha de publicación : Jun-2010
Editor: Elsevier
Resumen: This paper presents a signal analysis methodology to validate (detect) and reconstruct the missing and false data of a large set of flow meters in the telecontrol system of a water distribution network. The proposed methodology is based on two time-scale forecasting models: a daily model based on a ARIMA time series, while the 10-min model is based on distributing the daily flow using a 10-min demand pattern. The demand patterns have been determined using two methods: correlation analysis and an unsupervised fuzzy logic classification, named LAMDA algorithm. Finally, the proposed methodology has been applied to the Barcelona water distribution network, providing very good results.
Descripción : 12 páginas, 16 figuras, 1 tabla.-- El PDF es la versión pre-print.-- et al.
Versión del editor: http://dx.doi.org/10.1016/j.conengprac.2010.03.003
URI : http://hdl.handle.net/10261/39348
ISSN: 0967-0661
DOI: 10.1016/j.conengprac.2010.03.003
Citación : Control Engineering Practice 18(6): 640-651 (2010)