Título: | Readiness of the ATLAS Tile Calorimeter for LHC collisions |
Autor: | Aad, G.; Zutshi, V.; ATLAS Collaboration; Amorós, Gabriel CSIC; Cabrera, Susana CSIC ORCID; Castillo, Mª Victoria CSIC ORCID; Costa, María José CSIC ORCID; Escobar, Carlos CSIC ORCID ; Ferrer, Antonio CSIC ORCID; Fuster, Juan CSIC ORCID; García García, Carmen CSIC ORCID; González de la Hoz, Santiago CSIC ORCID CVN; Hernández Jiménez, Yesenia CSIC ORCID; Higón, Emilio CSIC ORCID; Irles Quiles, Adrián CSIC ORCID CVN ; Kaci, Mohamed CSIC; Lacasta Llácer, Carlos CSIC ORCID ; Lacuesta, Vicente CSIC; Martí García, Salvador; Miñano, Mercedes CSIC ORCID; Mitsou, Vasiliki A. CSIC ORCID ; Moles Valls, Regina CSIC ORCID; Moreno Llácer, María CSIC ORCID; Oliver García, Elena CSIC ORCID; Pérez García-Estañ, María Teresa CSIC; Ros, Eduardo CSIC ORCID; Salt, José CSIC ORCID; Sánchez Martínez, Javier CSIC ORCID; Sanchís Lozano, Miguel Ángel CSIC ORCID; Solans, Carlos CSIC; Torró Pastor, Emma CSIC ORCID; Valladolid Gallego, Eva CSIC; Valls Ferrer, Juan Antonio CSIC ORCID; Villaplana Pérez, Miguel CSIC ORCID; Vos, Marcel CSIC ORCID; Wildauer, Andreas CSIC | Fecha de publicación: | dic-2010 | Editor: | Springer Nature | Citación: | European Physical Journal C: Particles and Fields 70(4): 723-753 (2010) | Resumen: | The Tile hadronic calorimeter of the ATLAS detector has undergone extensive testing in the experimental hall since its installation in late 2005. The readout, control and calibration systems have been fully operational since 2007 and the detector has successfully collected data from the LHC single beams in 2008 and first collisions in 2009. This paper gives an overview of the Tile Calorimeter performance as measured using random triggers, calibration data, data from cosmic ray muons and single beam data. The detector operation status, noise characteristics and performance of the calibration systems are presented, as well as the validation of the timing and energy calibration carried out with minimum ionising cosmic ray muons data. The calibration systems’ precision is well below the design value of 1%. The determination of the global energy scale was performed with an uncertainty of 4%. | Descripción: | The ATLAS Collaboration.-- et al. | Versión del editor: | https://doi.org/10.1140/epjc/s10052-010-1354-y | URI: | http://hdl.handle.net/10261/39162 | DOI: | 10.1140/epjc/s10052-010-1354-y | ISSN: | 1434-6044 | E-ISSN: | 1434-6052 |
Aparece en las colecciones: | (IFIC) Artículos (IMB-CNM) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
ATLAS-liquid.pdf | 2,16 MB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
SCOPUSTM
Citations
59
checked on 13-mar-2024
WEB OF SCIENCETM
Citations
49
checked on 27-feb-2024
Page view(s)
400
checked on 18-mar-2024
Download(s)
3
checked on 18-mar-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.