Título: | Preconcentration and matrix separation of precious metals in geological and related materials using metalfix-chelamine resin prior to inductively coupled plasma mass spectrometry |
Autor: | Gómez Coedo, Aurora CSIC ; Dorado López, María Teresa CSIC ; Padilla, Isabel CSIC ORCID ; Alguacil, Francisco José CSIC ORCID | Palabras clave: | Precious metals Tetraethylenepentamine resin Matrix separation Platinum ores Inductively coupled plasma-mass spectrometry |
Fecha de publicación: | mar-1997 | Editor: | Elsevier | Citación: | Analytica Chimica Acta 340 (1-3) : 31-40 (1997) | Resumen: | A method for determining Au, Pt, Pd, Ir and Rh in ores and silicates and Fe-formation rocks is described. Sample decomposition was carried out with aqua regia and HF, followed by fusion of any insoluble residue with Na22O2 in a glassycarbon crucible. The precious metals were separated, in 1.2 mol dm−3 HCl media, from the matrix elements by ion-exchange, using a mini-column with tetraethylenepentamine (metalfix-chelamine) resin. The resin was destroyed with HNO3 and H2O2 in a high-pressure vessel assisted by microwave heating, and the precious elements were determined by flow-injection inductively coupled plasma mass spectrometry. The sample treatment, optimization of analytical variables and measurable concentration levels are discussed. The limits of quantification (10 sdn − 1) calculated from a procedural blank sample solution were 4.0, 2.0, 1.5, 0.8 and 0.5 ng g−1 for Au, Pt, Pd, Ir and Rh, respectively. The accuracy of the proposed method was tested by determining these elements in SARM 7 platinum-ore reference material. For all the analytes, the relative standard deviation of the combined dissolution, separation and determination methods was below 3.5% (n = 6). | Versión del editor: | http://dx.doi.org/10.1016/S0003-2670(96)00549-1 | URI: | http://hdl.handle.net/10261/38497 | DOI: | 10.1016/S0003-2670(96)00549-1 | ISSN: | 0003-2670 |
Aparece en las colecciones: | (CENIM) Artículos |
Mostrar el registro completo
CORE Recommender
SCOPUSTM
Citations
64
checked on 09-abr-2024
WEB OF SCIENCETM
Citations
58
checked on 27-feb-2024
Page view(s)
313
checked on 19-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.