Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/37313
COMPARTIR / EXPORTAR:
SHARE CORE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Raposo Bejines, Francisco | - |
dc.contributor.author | Fernández-Cegrí, Victoria | - |
dc.contributor.author | Rubia, M. Ángeles de la | - |
dc.contributor.author | Borja Padilla, Rafael | - |
dc.date.accessioned | 2011-06-30T06:56:49Z | - |
dc.date.available | 2011-06-30T06:56:49Z | - |
dc.date.issued | 2010-10 | - |
dc.identifier.citation | Trends in Analytical Chemistry 29(9): 1082-1091 (2010) | es_ES |
dc.identifier.issn | 0165-9936 | - |
dc.identifier.uri | http://hdl.handle.net/10261/37313 | - |
dc.description | 10 páginas, 2 figuras, 5 tablas.-- et al. | es_ES |
dc.description.abstract | Chemical oxygen demand (COD) is a critical analytical parameter in waste and wastewater treatment, more specifically in anaerobic digestion, although little is known about the quality of measuring COD of anaerobic digestion samples. Proficiency testing (PT) is a powerful tool that can be used to test the performance achievable in the participants’ laboratories, so we carried out a second PT of COD determination in samples considered “difficult” to analyze (i.e. solid samples and liquid samples with high concentrations of suspended solids). The results obtained (based on acceptable z-score values) may be considered satisfactory. When compared with the results of a previous similar scheme, the overall performance improved by around 30%, again demonstrating that analytical performance can be improved by regular participation in PT. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | Elsevier | es_ES |
dc.rights | closedAccess | es_ES |
dc.subject | Anaerobic digestion | es_ES |
dc.subject | Chemical oxygen demand | es_ES |
dc.subject | Interlaboratory study | es_ES |
dc.subject | Liquid sample | es_ES |
dc.subject | Proficiency testing (PT) | es_ES |
dc.subject | Solid sample | es_ES |
dc.subject | Suspended solids | es_ES |
dc.subject | Waste treatment | es_ES |
dc.subject | Wastewater treatment | es_ES |
dc.title | Quality improvement in determination of chemical oxygen demand in samples considered difficult to analyze, through participation in proficiency-testing schemes | es_ES |
dc.type | artículo | es_ES |
dc.identifier.doi | 10.1016/j.trac.2010.06.005 | - |
dc.description.peerreviewed | Peer reviewed | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.trac.2010.06.005 | es_ES |
dc.type.coar | http://purl.org/coar/resource_type/c_6501 | es_ES |
item.languageiso639-1 | en | - |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | none | - |
item.openairetype | artículo | - |
Aparece en las colecciones: | (IG) Artículos |
CORE Recommender
SCOPUSTM
Citations
25
checked on 04-abr-2024
WEB OF SCIENCETM
Citations
25
checked on 21-feb-2024
Page view(s)
281
checked on 22-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.