Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/266051
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

A Plethysmography Capacitive Sensor for Real-Time Monitoring of Volume Changes in Acute Heart Failure

AutorRando, Enrique CSIC; Pérez, Pablo CSIC; Fernández Scagliusi, Santiago; Medrano, Francisco Javier CSIC ORCID ; Huertas, Gloria CSIC ORCID; Yúfera, Alberto CSIC ORCID
Palabras claveHafnium
Electrodes
Legged locomotion
Monitoring
Real-time systems
Permittivity
Biomedical monitoring
Fecha de publicación23-jun-2021
EditorInstitute of Electrical and Electronics Engineers
CitaciónIEEE Transactions on Instrumentation and Measurement 70: 1-12 (2021)
ResumenA small, wearable, low-weight, and low-power-consumption device for plethysmography capacitive sensing is proposed herein. The device allows carrying out real-time monitoring of leg volume changes in patients suffering from heart failure (HF) conditions. The dynamic of fluid overload in patients with acute HF serves as a prognosis marker for this type of severe disease and, consequently, these patients can benefit from a wearable monitoring system to measure their body volume evolution during and after hospitalization. Our approach is based on contactless capacitive wearable structures implemented by two different sensor realizations located in the ankle: 180°-parallel capacitor plates (two modes of operations are compared, with the patient’s body connected to ground and to the average voltage between plates) and planar-parallel capacitor plates whose overlapped surface varies with the volume of the patient’s leg. Both realizations exhibit good sensitivity to leg volume changes. The acquisition of capacitance values is performed via a simple circuit that achieves notable performance in simulated volume analysis. A preliminary pilot clinical prototype is described as well.
Versión del editorhttp://dx.doi.org/10.1109/TIM.2021.3091483
URIhttp://hdl.handle.net/10261/266051
DOI10.1109/TIM.2021.3091483
Identificadoresdoi: 10.1109/TIM.2021.3091483
issn: 0018-9456
e-issn: 1557-9662
Aparece en las colecciones: (IBIS) Artículos
(IMSE-CNM) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

6
checked on 10-abr-2024

WEB OF SCIENCETM
Citations

6
checked on 26-feb-2024

Page view(s)

62
checked on 18-abr-2024

Download(s)

9
checked on 18-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.