Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/266051
COMPARTIR / EXPORTAR:
SHARE CORE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Título: | A Plethysmography Capacitive Sensor for Real-Time Monitoring of Volume Changes in Acute Heart Failure |
Autor: | Rando, Enrique CSIC; Pérez, Pablo CSIC; Fernández Scagliusi, Santiago; Medrano, Francisco Javier CSIC ORCID ; Huertas, Gloria CSIC ORCID; Yúfera, Alberto CSIC ORCID | Palabras clave: | Hafnium Electrodes Legged locomotion Monitoring Real-time systems Permittivity Biomedical monitoring |
Fecha de publicación: | 23-jun-2021 | Editor: | Institute of Electrical and Electronics Engineers | Citación: | IEEE Transactions on Instrumentation and Measurement 70: 1-12 (2021) | Resumen: | A small, wearable, low-weight, and low-power-consumption device for plethysmography capacitive sensing is proposed herein. The device allows carrying out real-time monitoring of leg volume changes in patients suffering from heart failure (HF) conditions. The dynamic of fluid overload in patients with acute HF serves as a prognosis marker for this type of severe disease and, consequently, these patients can benefit from a wearable monitoring system to measure their body volume evolution during and after hospitalization. Our approach is based on contactless capacitive wearable structures implemented by two different sensor realizations located in the ankle: 180°-parallel capacitor plates (two modes of operations are compared, with the patient’s body connected to ground and to the average voltage between plates) and planar-parallel capacitor plates whose overlapped surface varies with the volume of the patient’s leg. Both realizations exhibit good sensitivity to leg volume changes. The acquisition of capacitance values is performed via a simple circuit that achieves notable performance in simulated volume analysis. A preliminary pilot clinical prototype is described as well. | Versión del editor: | http://dx.doi.org/10.1109/TIM.2021.3091483 | URI: | http://hdl.handle.net/10261/266051 | DOI: | 10.1109/TIM.2021.3091483 | Identificadores: | doi: 10.1109/TIM.2021.3091483 issn: 0018-9456 e-issn: 1557-9662 |
Aparece en las colecciones: | (IBIS) Artículos (IMSE-CNM) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
accesoRestringido.pdf | 15,38 kB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
SCOPUSTM
Citations
6
checked on 10-abr-2024
WEB OF SCIENCETM
Citations
6
checked on 26-feb-2024
Page view(s)
62
checked on 18-abr-2024
Download(s)
9
checked on 18-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric