Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/231124
COMPARTIR / EXPORTAR:
SHARE CORE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Título: | Evaporative mist cooling as heat dissipation technique: Experimental assessment and modelling |
Autor: | Tenorio Ríos, José Antonio ; Toral Ulloa, Francisco CSIC ORCID | Fecha de publicación: | 2020 | Editor: | Multidisciplinary Digital Publishing Institute | Citación: | Applied Sciences (Switzerland) 10 (2020) | Resumen: | The severity of extreme weather conditions brought on by climate change are conditioning quality of life, economic development, and well-being in today's cities. Conventional measures have been shown to be insufficient for tackling climate change and must be supplemented with ecofriendly approaches. Hence, the scientific community's endeavor to develop natural cooling techniques that lower energy consumption while delivering satisfactory comfort levels. For its simplicity and low cost, evaporative cooling has gained in popularity in recent years. The substantial cooling power to be drawn from evaporative mist cooling, makes it an attractive alternative to conventional systems. Research conducted to date on the technique has focused on producing cold air, whilst cooling the water involved has been neither assessed nor experimentally validated. No readily applicable simplified model for the system able to use operating parameters as input variables has been defined either. The present study consequently aimed to experimentally assess the cooling power of the evaporation of sprayed water and experimentally validate a simplified model to assess and design such systems. The findings confirmed the cooling power of the technique, with declines in water temperature of up to 6 °C, and with it the promise afforded by this natural air conditioning method. Finally, simplified model developed allows to evaluate this technique like a conventional system for producing fresh water. | Versión del editor: | http://dx.doi.org/10.3390/app10176026 | URI: | http://hdl.handle.net/10261/231124 | DOI: | 10.3390/app10176026 | Identificadores: | doi: 10.3390/app10176026 issn: 2076-3417 |
Aparece en las colecciones: | (IETCC) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
Evaporative Mist Cooling as Heat Dissipation.pdf | 5,23 MB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
Page view(s)
82
checked on 21-abr-2024
Download(s)
215
checked on 21-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.