Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/214556
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

High sensitivity detection of extracellular vesicles immune-captured from urine by conventional flow cytometry

AutorCampos-Silva, Carmen CSIC ORCID; Suarez, Henar; Jara-Acevedo, Ricardo; Linares-Espinós, Estefanía; Martínez-Piñeiro, Luis; Yáñez-Mó, María; Valés-Gómez, Mar CSIC ORCID
Fecha de publicación2019
EditorSpringer Nature
CitaciónScientific Reports 9(1): 2042 (2019)
ResumenExtracellular vesicles (EVs) provide an invaluable tool to analyse physiological processes because they transport, in biological fluids, biomolecules secreted from diverse tissues of an individual. EV biomarker detection requires highly sensitive techniques able to identify individual molecules. However, the lack of widespread, affordable methodologies for high-throughput EV analyses means that studies on biomarkers have not been done in large patient cohorts. To develop tools for EV analysis in biological samples, we evaluated here the critical parameters to optimise an assay based on immunocapture of EVs followed by flow cytometry. We describe a straightforward method for EV detection using general EV markers like the tetraspanins CD9, CD63 and CD81, that allowed highly sensitive detection of urinary EVs without prior enrichment. In proof-of-concept experiments, an epithelial marker enriched in carcinoma cells, EpCAM, was identified in EVs from cell lines and directly in urine samples. However, whereas EVs isolated from 5–10 ml of urine were required for western blot detection of EpCAM, only 500 μl of urine were sufficient to visualise EpCAM expression by flow cytometry. This method has the potential to allow any laboratory with access to conventional flow cytometry to identify surface markers on EVs, even non-abundant proteins, using minimally processed biological samples.
Versión del editorhttp://dx.doi.org/10.1038/s41598-019-38516-8
URIhttp://hdl.handle.net/10261/214556
DOI10.1038/s41598-019-38516-8
Identificadoresdoi: 10.1038/s41598-019-38516-8
e-issn: 2045-2322
pmid: 30765839
Aparece en las colecciones: (CNB) Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato
Mar Valés-Gómez - Sci. Rep. - 2019.pdf3,8 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

PubMed Central
Citations

58
checked on 24-abr-2024

SCOPUSTM   
Citations

98
checked on 19-abr-2024

WEB OF SCIENCETM
Citations

92
checked on 29-feb-2024

Page view(s)

172
checked on 23-abr-2024

Download(s)

140
checked on 23-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


Artículos relacionados:


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.