Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/19775
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Campo DC Valor Lengua/Idioma
dc.contributor.authorBadea, Mihaela-
dc.contributor.authorNistor, Catalin-
dc.contributor.authorGoda, Yasuhiro-
dc.contributor.authorFujimoto, Shigeru-
dc.contributor.authorDosho, Shin-
dc.contributor.authorDanet, Andrei-
dc.contributor.authorBarceló, Damià-
dc.contributor.authorVentura, Francesc-
dc.contributor.authorEmnéus, Jenny-
dc.date.accessioned2009-12-22T09:19:15Z-
dc.date.available2009-12-22T09:19:15Z-
dc.date.issued2003-06-11-
dc.identifier.citationThe Analyst 128(7): 849-856 (2003)en_US
dc.identifier.issn0003-2654-
dc.identifier.urihttp://hdl.handle.net/10261/19775-
dc.description8 pages, 5 figures, 5 tables.-- Printed version published Jul 2003.-- Supporting iniformation available at: http://www.rsc.org/suppdata/an/b3/b302110f/en_US
dc.description.abstractThis paper describes the application and evaluation of a competitive enzyme flow injection immunoassay (EFIIA) for screening of alkylphenol ethoxylate (APEO) surfactants in different water samples based on a generic immunoassay system previously developed (see E. Burestedt, C Nistor, U. Schagerlöf and J. Emnéus, Anal. Chem., 2000, 72, 4171–4177). The detection limits for octylphenol ethoxylates (OPEOs), nonylphenol ethoxylates (NPEOs), and nonylphenol (NP) were 0.5 µg l–1, between 2 and 3 µg l–1, and 50 µg l–1, respectively, with a sample throughput of 6 h–1 (i.e., for triplicate analysis of each sample). Different OPEOs and NPEOs were highly cross-reactive within the assay, with sensitivities in the same order of magnitude for all the ethoxylates tested, thus the result obtained by the EFIIA method could be used as an alkylphenol ethoxylate index. No or minor matrix effects with recoveries between 70–120% for the reference analyte NPEO10 in tap, and surface water, and acceptable for rainwater, were observed. Influent and effluent surfactant containing wastewater samples were analysed by EFIIA, LC-MS, LC-Fluoresence (LC-FL), and a commercial microplate ELISA. High recoveries for different concentrations of APEO10 spiked into a 200 times diluted raw influent and effluent wastewater were achieved with the EFIIA method, however, the found APEO content of the same diluted wastewater samples, before spiking, could not be correlated directly to the chromatographic result by any of the immunoassays, and the possible reasons for this are discussed. The same trend of decreasing APEO content from influent to effluent wastewater could, however, be followed for all methods employed.en_US
dc.description.sponsorshipFinancial support from the European Community (EC No. ENV4-CT97–0476, IC15-CT98–0119, IC15-CT98–0138 and ICA-1999–10017), Spanish project PPQ2001–4954-E, the Swedish Foundation for Strategic Environmental Research (MISTRA), the Swedish Council for Forestry and Agricultural Research (SJFR), the Swedish Research Council (Vetenskapsrådet), the Swedish Environmental Protection Agency (NVV-Naturvårdsverket), Kungliga Fysiografiska Sällskapet i Lund, and Knut och Alice Wallenbergs Stiftelse.en_US
dc.format.extent117498 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoengen_US
dc.publisherRoyal Society of Chemistry (UK)en_US
dc.rightsopenAccessen_US
dc.subjectEnzyme flow injection immunoassay (EFIIA)en_US
dc.subjectAlkylphenolethoxylate (APEO)en_US
dc.subjectLiquid chromatography–mass spectrometry (LC-MS)en_US
dc.titleA flow immunoassay for alkylphenol ethoxylate surfactants and their metabolites—questions associated with cross-reactivity, matrix effects, and validation by chromatographic techniquesen_US
dc.typeartículoen_US
dc.identifier.doi10.1039/b302110f-
dc.description.peerreviewedPeer revieweden_US
dc.relation.publisherversionhttp://dx.doi.org/10.1039/b302110fen_US
dc.identifier.e-issn1364-5528-
dc.type.coarhttp://purl.org/coar/resource_type/c_6501es_ES
item.openairetypeartículo-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextWith Fulltext-
item.languageiso639-1en-
Aparece en las colecciones: (IDAEA) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato
Badea_Mihaela_et_al.pdf114,74 kBAdobe PDFVista previa
Visualizar/Abrir
Show simple item record

CORE Recommender

SCOPUSTM   
Citations

11
checked on 17-abr-2024

WEB OF SCIENCETM
Citations

10
checked on 26-feb-2024

Page view(s)

360
checked on 19-abr-2024

Download(s)

378
checked on 19-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.