Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/195285
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Improved 242Pu(n, γ) thermal cross section combining activation and prompt gamma anal

AutorLerendegui-Marco, J.; Guerrero, C. CSIC; Belgya, T.; Maróti, B.; Eberhardt, K.; Düllmann, C.E.; Junghans, A. R.; Mokry, C.; Quesada, José Manuel; Runke, J.; Thörle-Pospiech, P.
Fecha de publicaciónmay-2019
EditorSpringer Nature
CitaciónEuropean Physical Journal A - Hadrons and Nuclei 55(5): 63 (2019)
ResumenA good knowledge of the radiative capture cross section of 242Pu is required for innovative nuclear reactor studies, especially for MoX fuel reactors. However, the experimental data available show discrepancies in the energy regions of interest: the thermal point and the keV region. Previous experimental results of the thermal cross section deviate from each other by 20% and these discrepancies are reflected also in the evaluated libraries, each of them giving more credit to different data sets. A recent measurement by Genreith et al. did not succeed to solve the existing discrepancy due to the large uncertainties and correction factors in the analysis. This work presents a new measurement of the thermal capture cross section of 242Pu carried out in the Budapest Research Reactor using the same thin targets of a previous measurement at n_TOF-EAR1, each containing 30mg of 99.995% pure 242Pu . The combined analysis of the full prompt γ -ray spectrum and the 243Pu decay has led to three compatible values for the thermal cross section. Their average value, 18.9(9)b, has an improved accuracy compared to recent measurements. Leaving aside the activation value of Genreith using an outdated intensity value for the 84 keV decay line of 243Pu , our average result is in very good agreement with the JEFF-3.2 evaluation and all the previous measurements, with the exception of the highest value 22.5(11)b reported by Marie et al., which has a strong influence in the ENDF evaluation.
Versión del editorhttp://dx.doi.org/10.1140/epja/i2019-12730-6
URIhttp://hdl.handle.net/10261/195285
DOI10.1140/epja/i2019-12730-6
ISSN1434-6001
E-ISSN1434-601X
Aparece en las colecciones: (CNA) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,35 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

WEB OF SCIENCETM
Citations

2
checked on 18-feb-2024

Page view(s)

181
checked on 23-abr-2024

Download(s)

30
checked on 23-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.