Bigaussian wavefront model for normal and keratoconic eyes

AutorRozema, J. J.; Rodríguez, Pablo; Navarro, Rafael CSIC ORCID; Koppen, Carina
Fecha de publicación2017
EditorLippincott Williams & Wilkins
CitaciónOptometry and Vision Science 94(6): 680-687 (2017)
Resumen[Purpose]: To report bigaussian multivariate wavefront models capable of stochastically generating an unlimited amount of plausible wavefront data for either normal or keratoconic eyes.
[Methods]: The models use centroid wavefront data measured previously with an iTrace in 330 healthy right eyes and 122 keratoconic right eyes. These centroids were fitted to an 11th-order Zernike series, followed by principal component analysis to reduce dimensionality and remove correlations. The remaining parameters were then fitted to a sum of two multivariate Gaussian distributions. This fit then forms the core of the stochastic model, which may be used to generate synthetic data. Finally, the agreement between the original and synthetic data was tested using two one-sided t tests.
[Results]: For normal eyes, the first eigenvectors mostly represent pure Zernike polynomials, with a decreasing degree of purity with increasing order. For keratoconic eyes, eigenvector purity was considerably lower than for normal eyes. Depending on the data set, series of 22 to 29 eigenvectors were found sufficient for accurate wavefront reconstruction (i.e., root-mean-square errors below 0.05 μm). These eigenvectors were then used as a base for the stochastic models. In all models and all Zernike coefficients, the mean of the synthetic data was significantly equal to that of the original data (two one-sided t test, P > .05/75), but the variability of the synthetic data is often significantly lower (F test, P < .05/75).
[Conclusions]: This synthetic wavefront model may be safely used in calculations as an alternative to actual measurements should such data not be available.
Versión del editorhttps://doi.org/10.1097/OPX.0000000000001075
URIhttp://hdl.handle.net/10261/181769
DOI10.1097/OPX.0000000000001075
ISSN1040-5488
E-ISSN1538-9235
Aparece en las colecciones: (ICMA) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf59,24 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

PubMed Central
Citations

1
checked on 21-abr-2024

SCOPUSTM   
Citations

4
checked on 16-abr-2024

WEB OF SCIENCETM
Citations

2
checked on 22-feb-2024

Page view(s)

175
checked on 21-abr-2024

Download(s)

31
checked on 21-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


Artículos relacionados:


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.