English   español  
Please use this identifier to cite or link to this item: http://hdl.handle.net/10261/166004
Share/Impact:
Statistics
logo share SHARE logo core CORE   Add this article to your Mendeley library MendeleyBASE

Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Exportar a otros formatos:

Title

Geometric correction factor for transepithelial electrical resistance measurements in transwell and microfluidic cell cultures

AuthorsYeste Lozano, José; Illa, Xavi; Gutiérrez, Cristina; Solé, Montse; Guimerà, Anton; Villa, Rosa
KeywordsTransepithelial Electrical Resistance
Electrical Impedance Spectroscopy
Interdigitated Electrodes
Microfluidics
Transwell
Geometric Correction Factor
Issue Date18-Aug-2016
PublisherInstitute of Physics Publishing
CitationJournal of Physics D: Applied Physics 49(37):375401 (2016)
AbstractTransepithelial electrical resistance (TEER) measurements are regularly used in in vitro models to quantitatively evaluate the cell barrier function. Although it would be expected that TEER values obtained with the same cell type and experimental setup were comparable, values reported in the literature show a large dispersion for unclear reasons. This work highlights a possible error in a widely used formula to calculate the TEER, in which it may be erroneously assumed that the entire cell culture area contributes equally to the measurement. In this study, we have numerically calculated this error in some cell cultures previously reported. In particular, we evidence that some TEER measurements resulted in errors when measuring low TEERs, especially when using Transwell inserts 12 mm in diameter or microfluidic systems that have small chamber heights. To correct this error, we propose the use of a geometric correction factor (GCF) for calculating the TEER. In addition, we describe a simple method to determine the GCF of a particular measurement system, so that it can be applied retrospectively. We have also experimentally validated an interdigitated electrodes (IDE) configuration where the entire cell culture area contributes equally to the measurement, and it also implements minimal electrode coverage so that the cells can be visualized alongside TEER analysis.
Publisher version (URL)https://doi.org/10.1088/0022-3727/49/37/375401
URIhttp://hdl.handle.net/10261/166004
DOI10.1088/0022-3727/49/37/375401
ISSN0022-3727
Appears in Collections:(IMB-CNM) Artículos
Files in This Item:
File Description SizeFormat 
JPhysDApplPhys_2016_Jose_Yeste.pdfMain article1,5 MBAdobe PDFThumbnail
View/Open
Show full item record
Review this work
 

Related articles:


WARNING: Items in Digital.CSIC are protected by copyright, with all rights reserved, unless otherwise indicated.