Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/16525
Compartir / Impacto:
Título : The Silicon Cube detector
Autor : Matea, I., Adimi, N., Blank, B., Canchel, G., Giovinazzo, J., García Borge, María José, Domínguez-Reyes, Ricardo, Tengblad, Olof, Thomas, J.-C.
Palabras clave : Nuclear Physics
β decay
Charged particles
Angular correlations
Silicon detectors
Fecha de publicación : 16-jun-2009
Editor: Elsevier
Resumen: A new experimental device, the Silicon Cube detector, consisting of six double-sided silicon strip detectors placed in a compact geometry was developed at CENBG. Having a very good angular coverage and high granularity, it allows simultaneous measurements of energy and angular distributions of charged particles emitted from unbound nuclear states. In addition, large-volume Germanium detectors can be placed close to the collection point of the radioactive species to be studied. The setup is ideally suited for isotope separation on-line (ISOL)-type experiments to study multi-particle emitters and was tested during an experiment at the low-energy beam line of SPIRAL at GANIL.
Descripción : 5 pages, 1 table, 7 figures.--Printed version published Aug 21, 2009
Versión del editor: http://dx.doi.org/10.1016/j.nima.2009.06.016
URI : http://hdl.handle.net/10261/16525
ISSN: 0168-9002
DOI: 10.1016/j.nima.2009.06.016
Citación : Nuclear Instruments and Methods in Physics Research A 607(3): 576–580 (2009)