Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/164274
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Impedimetric label-free sensor for specific bacteria endotoxin detection by surface charge registration

AutorBrosel-Oliu, Sergi; Galyamin, Dmitry; Abramova, Natalia CSIC ORCID ; Muñoz Pascual, Francisco Javier; Bratov, Andrey
Palabras claveImpedimetric sensor
Surface charge
Interdigitated electrode array
Bacterial endotoxin
Concanavalin A
Fecha de publicación20-jul-2017
EditorElsevier
CitaciónElectrochimica Acta 243: 142-151 (2017)
ResumenAn impedimetric sensor based on a three dimensional electrode array modified with concanavalin A (Con A) was used for label-free detection of bacterial endotoxin: lipopolysaccharide (LPS) from Escherichia coli. The transducer permits the detection of the surface charge changes due to interaction of immobilized Con A biorecognition element and LPS of E. coli in test solution. The deposition of Con A on the surface was carried out using the layer-by-layer method with polyethyleneimine (PEI) polycation as an initial layer. The sensor surface characterization by means of electrochemical impedance spectroscopy technique allowed registering variations in superficial resistance provoked by surface charge changes and is demonstrated as an effective method to monitor sensor parameters at each modification step as well as to follow Con A – LPS reaction. In order to prevent non-specific adsorption of LPS on PEI covered surface different blocking strategies were tested to achieve the specific response between Con A and LPS. Results obtained in this work clearly show that blocking with bovine serum albumin (BSA) is not sufficient to prevent non-specific interactions of PEI and to ensure the selective biorecognition of LPS by Con A. To achieve more efficient PEI blocking a new method was proposed based on consecutive deposition of Con A-glycogen-Con A layers. Sensors modified with PEI-(Con A-Gly)2-Con A multilayers are shown to be highly sensitive, selective and reproducible. Presented biosensor is able to detect bacterial LPS in a very short detection time (20 min) with 2 μg mL−1 limit of detection, which is much lower than reported for other biosensors with Con A.
Versión del editorhttp://doi.org/10.1016/j.electacta.2017.05.060
URIhttp://hdl.handle.net/10261/164274
DOI10.1016/j.electacta.2017.05.060
ISSN0013-4686
Aparece en las colecciones: (IMB-CNM) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
ELECTACTA-S-17-00927-1.pdf1,65 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

27
checked on 21-abr-2024

WEB OF SCIENCETM
Citations

25
checked on 26-feb-2024

Page view(s)

358
checked on 23-abr-2024

Download(s)

403
checked on 23-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


Este item está licenciado bajo una Licencia Creative Commons Creative Commons