Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/164274
COMPARTIR / EXPORTAR:
SHARE CORE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Título: | Impedimetric label-free sensor for specific bacteria endotoxin detection by surface charge registration |
Autor: | Brosel-Oliu, Sergi; Galyamin, Dmitry; Abramova, Natalia CSIC ORCID ; Muñoz Pascual, Francisco Javier; Bratov, Andrey | Palabras clave: | Impedimetric sensor Surface charge Interdigitated electrode array Bacterial endotoxin Concanavalin A |
Fecha de publicación: | 20-jul-2017 | Editor: | Elsevier | Citación: | Electrochimica Acta 243: 142-151 (2017) | Resumen: | An impedimetric sensor based on a three dimensional electrode array modified with concanavalin A (Con A) was used for label-free detection of bacterial endotoxin: lipopolysaccharide (LPS) from Escherichia coli. The transducer permits the detection of the surface charge changes due to interaction of immobilized Con A biorecognition element and LPS of E. coli in test solution. The deposition of Con A on the surface was carried out using the layer-by-layer method with polyethyleneimine (PEI) polycation as an initial layer. The sensor surface characterization by means of electrochemical impedance spectroscopy technique allowed registering variations in superficial resistance provoked by surface charge changes and is demonstrated as an effective method to monitor sensor parameters at each modification step as well as to follow Con A – LPS reaction. In order to prevent non-specific adsorption of LPS on PEI covered surface different blocking strategies were tested to achieve the specific response between Con A and LPS. Results obtained in this work clearly show that blocking with bovine serum albumin (BSA) is not sufficient to prevent non-specific interactions of PEI and to ensure the selective biorecognition of LPS by Con A. To achieve more efficient PEI blocking a new method was proposed based on consecutive deposition of Con A-glycogen-Con A layers. Sensors modified with PEI-(Con A-Gly)2-Con A multilayers are shown to be highly sensitive, selective and reproducible. Presented biosensor is able to detect bacterial LPS in a very short detection time (20 min) with 2 μg mL−1 limit of detection, which is much lower than reported for other biosensors with Con A. | Versión del editor: | http://doi.org/10.1016/j.electacta.2017.05.060 | URI: | http://hdl.handle.net/10261/164274 | DOI: | 10.1016/j.electacta.2017.05.060 | ISSN: | 0013-4686 |
Aparece en las colecciones: | (IMB-CNM) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
ELECTACTA-S-17-00927-1.pdf | 1,65 MB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
SCOPUSTM
Citations
27
checked on 21-abr-2024
WEB OF SCIENCETM
Citations
25
checked on 26-feb-2024
Page view(s)
358
checked on 23-abr-2024
Download(s)
403
checked on 23-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
Este item está licenciado bajo una Licencia Creative Commons