Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/158563
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Energy-sensitive ion- and cathode-luminescent radiation-beam monitors based on multilayer thin-film designs

AutorGil-Rostra, J. CSIC ORCID; Ferrer, F. J. CSIC ORCID; Espinós, J.P. CSIC ORCID; González-Elipe, Agustín R. CSIC ORCID; Yubero, Francisco CSIC ORCID
Palabras claveBeam-energy monitoring
Cathodoluminescence
Ion luminescence
Rare-earth phosphors
Radiation-beam monitor
Fecha de publicación2017
EditorAmerican Chemical Society
CitaciónACS Applied Materials and Interfaces 9(19): 16313-16320 (2017)
ResumenA multilayer luminescent design concept is presented to develop energy-sensitive radiation-beam monitors on the basis of colorimetric analysis. Each luminescent layer within the stack consists of rare-earth-doped transparent oxides of optical quality and a characteristic luminescent emission under excitation with electron or ion beams. For a given type of particle beam (electron, protons, α particles, etc.), its penetration depth and therefore its energy loss at a particular buried layer within the multilayer stack depend on the energy of the initial beam. The intensity of the luminescent response of each layer is proportional to the energy deposited by the radiation beam within the layer, so characteristic color emission will be achieved if different phosphors are considered in the layers of the luminescent stack. Phosphor doping, emission efficiency, layer thickness, and multilayer structure design are key parameters relevant to achieving a broad colorimetric response. Two case examples are designed and fabricated to illustrate the capabilities of these new types of detector to evaluate the kinetic energy of either electron beams of a few kilo-electron volts or α particles of a few mega-electron volts.
URIhttp://hdl.handle.net/10261/158563
DOI10.1021/acsami.7b01175
Identificadoresdoi: 10.1021/acsami.7b01175
issn: 1944-8244
e-issn: 1944-8252
Aparece en las colecciones: (ICMS) Artículos
(CNA) Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato
radiation-beam_monitors_multilayer_thin-film_designs.doc1,93 MBMicrosoft WordVisualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

11
checked on 22-abr-2024

WEB OF SCIENCETM
Citations

10
checked on 25-feb-2024

Page view(s)

305
checked on 23-abr-2024

Download(s)

118
checked on 23-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.