Título: | The use of agar gelled electrolyte for in situ electrochemical measurements on metallic cultural heritage |
Autor: | Ramírez Barat, Blanca CSIC ORCID ; Cano Díaz, Emilio CSIC ORCID | Palabras clave: | Polymer electrolyte Cultural Heritage EIS Bronze Agar |
Fecha de publicación: | 2015 | Editor: | Elsevier | Citación: | Electrochimica Acta 182: 751-762 (2015) | Resumen: | © 2015 Elsevier Ltd. All rights reserved. Electrochemical techniques, such as electrochemical impedance spectroscopy (EIS), are widely used for corrosion studies. However, their applicability to studies on metallic cultural heritage has been less spread due to the practical difficulties of performing measurements in-situ on sculptures or monuments. One interesting approach to this application is the use of gel polymer electrolytes (GP-E) to overcome the difficulties of handling liquid electrolytes on irregular leaning surfaces. In this paper, the behavior of an agar gelled electrolyte with a portable cell is evaluated for EIS measurements over three types of bronze coupons, and compared with a traditional liquid cell. The influence of the addition of agar in the reproducibility and repeatability of measurements is assessed, as well as the possible interaction of agar with the corrosion process. Results show that, although agar slightly accelerates the anodic process, it does not significantly affect the cathodic reaction and does not introduce new reactions in the corrosion mechanism. It is demonstrated that the GP-E allows obtaining reproducible and good quality EIS spectra, comparable to the liquid cell. Hence, it can be used for comparative in-situ measurements, being a very valuable tool for the evaluation of patina and coatings on metal cultural heritage. | Versión del editor: | http://dx.doi.org/10.1016/j.electacta.2015.09.116 | URI: | http://hdl.handle.net/10261/129016 | DOI: | 10.1016/j.electacta.2015.09.116 | Identificadores: | doi: 10.1016/j.electacta.2015.09.116 issn: 0013-4686 |
Aparece en las colecciones: | (CENIM) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
The use of agar gelled electrolyte-postprint_Digital.CSIC.pdf | 811,61 kB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
SCOPUSTM
Citations
42
checked on 21-abr-2024
WEB OF SCIENCETM
Citations
36
checked on 25-feb-2024
Page view(s)
281
checked on 24-abr-2024
Download(s)
230
checked on 24-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.