Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/12157
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Campo DC Valor Lengua/Idioma
dc.contributor.authorGuillaume, L. Erny-
dc.contributor.authorElvira, Carlos-
dc.contributor.authorSan Román, Julio-
dc.contributor.authorCifuentes, Alejandro-
dc.date.accessioned2009-04-07T09:36:31Z-
dc.date.available2009-04-07T09:36:31Z-
dc.date.issued2006-02-
dc.identifier.citationElectrophoresis, vol. 27, no5-6, pp. 1041-1049en_US
dc.identifier.issn0173-0835-
dc.identifier.urihttp://hdl.handle.net/10261/12157-
dc.description.abstractIn this work, a comparative study on the use of different polymers as physically adsorbed coatings for Capillary Electrophoresis (CE) is presented. It is demonstrated that the use of ad hoc synthesized polymers as coatings allows tailoring the electroosmotic flow (EOF) in CE increasing the flexibility of this analytical technique. Namely, different polymers were synthesized at our laboratory using different percentages of ethylpyrrolidine methacrylate (EpyM) and N,N-dimethylacrylamide (DMA). Thus, by modifying the percentage of EpyM and DMA monomers it is possible to manipulate the positive charge of the copolymer, varying the global electrical charge on the capillary wall and with that the EOF. These coated capillaries are obtained by simply flushing a given EpyM-DMA aqueous solution into bare silica capillaries. It is shown that by using these coated capillaries at adequate pHs, faster or more resolved CE separations can be achieved depending on the requirements of each analysis. Moreover, it is demonstrated that these coated capillaries reduce the electrostatic adsorption of basic proteins onto the capillary wall. Furthermore, EpyM-DMA coatings allow the reproducible chiral separation of enantiomers through the partial filling technique. The EpyM-DMA coated capillaries are demonstrated to provide reproducible EOF values independently of the pH and polymer composition with % RSD values lower than 2 % for the same day. It is also demonstrated that the coating procedure is reproducible between capillaries. The compatibility of this coating protocol with CE in microchips is discussed.en_US
dc.format.extent284312 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoengen_US
dc.publisherWiley-VCHen_US
dc.rightsopenAccessen_US
dc.subjectCapillary coatingen_US
dc.subjectphysically adsorbeden_US
dc.subjectprotein separationen_US
dc.subjectChiral separationen_US
dc.titleCAPILLARY ELECTROPHORESIS USING COPOLYMERS OF DIFFERENT COMPOSITION AS PHYSICAL COATINGS. A COMPARATIVE STUDY.en_US
dc.typeartículoen_US
dc.identifier.doi10.1002/elps.200500692-
dc.description.peerreviewedPeer revieweden_US
dc.relation.publisherversionhttp://dx.doi.org/10.1002/elps.200500692en_US
dc.type.coarhttp://purl.org/coar/resource_type/c_6501es_ES
item.cerifentitytypePublications-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextWith Fulltext-
item.languageiso639-1en-
item.openairetypeartículo-
Aparece en las colecciones: (IFI) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato
Electrophoresis 27 _2006_ 1041-1049.pdf277,65 kBAdobe PDFVista previa
Visualizar/Abrir
Show simple item record

CORE Recommender

SCOPUSTM   
Citations

38
checked on 25-abr-2024

WEB OF SCIENCETM
Citations

36
checked on 19-feb-2024

Page view(s)

443
checked on 22-abr-2024

Download(s)

396
checked on 22-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.