Título

Eigencorneas: application of principal component analysis to corneal topography

AutorRodríguez, Pablo; Navarro, Rafael CSIC ORCID; Rozema, J. J.
Palabras claveZernike polynomials
Corneal topography
Principal component analysis
Corneal model
Fecha de publicación2014
EditorJohn Wiley & Sons
CitaciónOphthalmic and Physiological Optics 34(6): 667-677 (2014)
Resumen[Purpose]: To determine the minimum number of orthonormal basis functions needed to accurately represent the great majority of corneal topographies from a normal population. [Methods]: Principal Component Analysis was applied to the elevation topographies of the anterior and posterior corneal surfaces and central thickness of 368 eyes of 184 healthy subjects. PCA was applied directly to the input elevation data points and after fitting them to Zernike polynomials (up to 8th order, 8 mm diameter). The anterior and posterior surfaces, as well as right eye and left eye data, were analysed both separately and jointly. A threshold based on the amount of explained variance (99%) was applied to determine the minimum number of basis functions (eigencorneas) or degrees of freedom (DoF) in the population. [Results]: The eigenvectors directly obtained from elevation data resemble Zernike polynomials. The separate principal component analysis on the Zernike coefficients of anterior and posterior surfaces yielded 5 and 9 DoF, respectively. An additional reduction to 11 DoF (instead of 15 DoF) was achieved when performing a joint PCA that included both surfaces as well as central thickness. Finally, a further reduction was obtained by pooling right and left eye data together, to only 18 DoF. [Conclusions]: The combination of Zernike fit and Principal Component Analysis yields a strong reduction of dimensionality of elevation topography data, to only 19 independent parameters (18 DoF plus population average), which indicates a high degree of correlation existing between anterior and posterior surfaces, and between eyes. The resulting eigencorneas are especially well suited for practical applications, as they are uncorrelated and orthonormal linear combinations of Zernike polynomials.
URIhttp://hdl.handle.net/10261/118280
DOI10.1111/opo.12155
Identificadoresdoi: 10.1111/opo.12155
issn: 0275-5408
e-issn: 1475-1313
Aparece en las colecciones: (ICMA) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

9
checked on 24-abr-2024

WEB OF SCIENCETM
Citations

9
checked on 23-feb-2024

Page view(s)

250
checked on 23-abr-2024

Download(s)

100
checked on 23-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.