Use of rare earth salts as electrochemical corrosion inhibitors for an Al-Li-Cu (8090) alloy in 3.56% NaCl

AutorDavó, B.; Damborenea, Juan de CSIC ORCID ; Damborenea, Juan de CSIC ORCID
Palabras claveXPS
Corrosion
Lanthanides salts
Aluminium-lithium alloys
Inhibition
Fecha de publicación2004
EditorElsevier
CitaciónElectrochimica Acta 49: 4957-4965 (2004)
ResumenAlloys used in the aeronautical industry, mainly of the series 7xxx and 2xxx, are liable to suffer several types of corrosion attack due to the fact that they are exposed to humid atmospheres of different aggressiveness. For this reason they are protected by surface treatments that can lengthen their service life. These treatments are mainly based on the use of chromates in anodic films, in conversion layers, or as inhibitor pigments in paint system primer coatings. However, in view of the high toxicity of chromates, viable alternatives are being researched to replace them. The literature includes a number of studies focused on the use of rare earth salts as inhibitors that can offer good levels of protection on Al-Zn-Mg-Cu and Al-Cu-Mg alloys. On the other hand, the need to reduce the weight of aeronautical structures means that research continues to be carried out on lightweight aluminium alloys such as Al-Li. The authors have not found references on the inhibition of this type of alloys, which may be of interest in the future. This work presents the results of localized corrosion inhibition on the Al-Li-Cu alloy 8090 T-8171 in 3.56% NaCl by means of the addition of CeCl3 and LaCl3 as inhibitors. The corrosion/inhibition mechanism and kinetics have been studied using electrochemical and surface analysis techniques (SEM, EDS, XPS). The inhibiting ability of the two salts in this system has been compared for the inhibitor concentrations used. © 2004 Elsevier Ltd. All rights reserved.
URIhttp://hdl.handle.net/10261/114531
DOI10.1016/j.electacta.2004.06.008
Identificadoresdoi: 10.1016/j.electacta.2004.06.008
issn: 0013-4686
Aparece en las colecciones: (CENIM) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

157
checked on 18-abr-2024

WEB OF SCIENCETM
Citations

140
checked on 27-feb-2024

Page view(s)

315
checked on 18-abr-2024

Download(s)

125
checked on 18-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.